Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.399
Filtrar
1.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591274

RESUMO

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Adulto , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
2.
J Back Musculoskelet Rehabil ; 37(3): 611-616, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38517767

RESUMO

BACKGROUND: The clavicle is recognized as the bone most vulnerable to fractures. Moreover, approximately 80% of fractures occur in the middle third of the clavicle. Conservative treatment is associated with a higher rate of nonunion, while surgical treatment of fracture via internal fixation may have a variety of postoperative complications. Therefore, to improve patient satisfaction and reduce the complications related to internal fixation techniques, we modified the surgical approach to external fixation. OBJECTIVE: The purpose of this study was to assess the modified intervention's prospects for clinical application. METHODS: A total of 36 patients with middle clavicle fractures were treated with screw-rod external fixation between April 2015 and October 2019. We observed the operative time, intraoperative blood loss, length of hospital stay, and fracture healing time. The patients were followed up regularly, and the clinical efficacy of the modified intervention was evaluated. Finally, the patients' shoulder function was assessed based on the disabilities of the arm, shoulder, and hand (DASH) score. RESULTS: For the screw-rod external fixation, the mean operative time was found to be 48.6 ± 6.8 min, the intraoperative blood loss was 30.6 ± 17.2 mL, the length of hospital stay was 4.5 ± 1.5 days, and the fracture healing time was 2.8 ± 0.4 months. Eventually, all the patients healed well, with the combined "excellent" and "good" rate of shoulder function being assessed to be as high as 94.44%. Furthermore, the DASH scores were all less than 10, with the average score being 4.65 ± 3.34. CONCLUSIONS: The screw-rod external fixation technique offers the advantages of convenience, reliability, and good aesthetics, suggesting that it could be used as an alternative treatment method for fractures of the middle third of the clavicle.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/lesões , Clavícula/cirurgia , Feminino , Masculino , Adulto , Fraturas Ósseas/cirurgia , Pessoa de Meia-Idade , Fixação de Fratura/métodos , Consolidação da Fratura/fisiologia , Duração da Cirurgia , Tempo de Internação , Resultado do Tratamento , Parafusos Ósseos , Fixação Interna de Fraturas/métodos
3.
Foot Ankle Int ; 45(5): 446-455, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501715

RESUMO

BACKGROUND: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization. METHODS: In this retrospective cohort study, patients with isolated AFD cases treated at our institution from 2011 to 2020 were reviewed. Inclusion criteria required radiographs depicting initial dislocation and appropriate reduction after Cast or ExFix immobilization. Exclusion criteria encompassed concomitant injuries, open fractures, conservative management as well as surgery performed within 48 hours or at a different facility. Patients were grouped by temporary treatment (Cast or ExFix). The primary endpoint was LOR prior to definitive surgery across various Lauge-Hansen types. RESULTS: The LOR rate was significantly higher in the cast group (40/152, 26.3%) compared to the ExFix group (5/191, 2.6%; P < .0001). In the cast group, LOR was associated with an increase in time to definitive surgery by a mean of 3 days (P < .002). During cast treatment, LOR was significantly more likely for pronation abduction (P = .001) and supination external rotation injuries (P < .0001), whereas no significant differences were observed for pronation external rotation (P = .006), supination adduction (P > .99), and fractures not classifiable (P > .99). CONCLUSION: In cases of AFDs resulting from supination external rotation or pronation abduction trauma according to the Lauge-Hansen classification, especially in the setting of an additional posterior malleolar fracture, primary application of external fixation should be considered to reduce the risk for secondary loss of reduction. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Fraturas do Tornozelo , Moldes Cirúrgicos , Fratura-Luxação , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fratura-Luxação/cirurgia , Fixação de Fratura/métodos , Idoso , Estudos de Coortes
4.
Artigo em Inglês | MEDLINE | ID: mdl-38537115

RESUMO

INTRODUCTION: External fixation of unstable ankle injuries is commonly done by orthopaedic surgeons. An improper technique can negate the benefits of the procedure and necessitate revision. This study sought to determine the risk factors for revision of external fixation of unstable ankle injuries. METHODS: Retrospective cohort at a level I academic trauma center of 120 consecutive patients underwent external fixation of an unstable ankle injury. Exclusion criteria included external fixation for reason other than fracture, inadequate intraoperative imaging, skeletal immaturity, and follow-up less than 30 days. Primary outcome measurement was revision of external fixation within 30 days. RESULTS: Ninety-seven patients met inclusion criteria. Eighteen (18.6%) underwent revision within 30 days of whom 5 (28%, P < 0.001) had a poor reduction intraoperatively. No patients with a good reduction required revision. Revised patients had a significantly higher talar tilt (P < 0.001) and were more likely to lack a first metatarsal pin (P = 0.018). Multivariate analysis revealed talar tilt >0.5° (odds ratio, 22.62; 95% confidence interval, 6.52 to 50.63) as an independent risk factor for revision. DISCUSSION: For external fixation of unstable ankle injuries, poor reduction quality is a risk factor for need for revision surgery. Orthopaedic surgeons should be critical of their final intraoperative assessment to prevent revision.


Assuntos
Traumatismos do Tornozelo , Fixação de Fratura , Humanos , Estudos Retrospectivos , Fixação de Fratura/métodos , Fixadores Externos , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fatores de Risco
5.
Med Sci Monit ; 30: e944136, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549240

RESUMO

BACKGROUND Tibial fractures, common in adults, are often treated with external or internal fixation methods. While effective, external fixation (EF) can lead to sexual dysfunction (SD), especially in young patients. This study aimed to assess SD in women undergoing EF versus internal fixation for tibial fractures. MATERIAL AND METHODS Sexual function and frequency of monthly sexual intercourse (SI) were evaluated using the Female Sexual Function Index (FSFI) before surgery, with the fixator, after at least 6 months following fixator removal in EF group, and after achieving bone union for at least 3 months in the IF group. RESULTS The EF group consisted of 107 (mean age 28.5 years; 19-40 years) and IF group consisted of 106 patients (mean age 32.1 years; 18-40 years). The duration of EF was an average of 4.7 months (range, 2.5-13 months). FSFI scores were significantly lower in the EF group compared to the IF group (9.33 versus 27.3, P<0.001). Also, there was no significant difference between the FSFI scores before EF and after EF was removed (34.22 versus 33.8, P=0.413). FSFI sub-group scores such as desire, arousal, lubrication, and orgasm were significantly lower in the EF group (P<0.001). The monthly average frequency of SI before surgery and after the removal of EF was 10.2 and 9.1, respectively, while this frequency was 2.56 when EF was present (P<0.001). CONCLUSIONS The quality and frequency of SI in women significantly deteriorate and decrease during the period of extremity fixation following tibial diaphyseal fractures treated with EF, but return to normal after removal.


Assuntos
Disfunções Sexuais Fisiológicas , Fraturas da Tíbia , Adulto , Humanos , Feminino , Estudos Retrospectivos , Fixadores Externos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Resultado do Tratamento
7.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484095

RESUMO

CASE: A 23-year-old right-hand dominant man presented with a high-velocity gunshot wound injury to the right thumb with severe soft-tissue damage, vascular injury, and large osseous defect of the right thumb metacarpal. The patient was successfully treated with metacarpophalangeal joint arthrodesis and metacarpal reconstruction using definitive external fixation, an intramedullary Kirschner wire, and use of the Masquelet bone grafting technique. CONCLUSION: The authors' treatment approach for a mangled thumb injury with definitive external fixation and utilization of the Masquelet technique resulted in restoration of a large osseous defect, avoidance of infection, and limited loss of mobility.


Assuntos
Traumatismos da Mão , Procedimentos de Cirurgia Plástica , Ferimentos por Arma de Fogo , Humanos , Masculino , Adulto Jovem , Fixadores Externos , Fixação de Fratura/métodos , Traumatismos da Mão/cirurgia , Polegar/cirurgia , Ferimentos por Arma de Fogo/cirurgia
8.
Proc Inst Mech Eng H ; 238(2): 187-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314816

RESUMO

This paper presents the outcome of a data review of patients treated with the IOS external fixation system at the Royal Stoke University Hospital: a fixation designed to meet four requirements for external fixation proposed in this paper. Demographic data and outcome were collected and assessed. From 69 initial patients, 64 patients (55 males and 9 females) had an average age of 35.9 years. The mean time to union was 127 days. There were no incidences of malunion, or refracture post fixation removal attributable to the treatment method. In addition, in this cohort, there was no incidence of pin tract infection resulting in osteomyelitis. Of all the factors assessed the only factor to have any significant effect on healing was smoking: an average delay of 31 days. An examination of RUST (radiographic union score tibia) and modified RUST scores illustrated a potential false negative of up to 80%. Hence, this study cannot support the use of either scoring system to diagnose fracture healing. IOS external fixation was shown to be an effective method for the treatment of unstable tibial fractures. The reduction at fixation removal was shown to be very good. There was no incidence of osteomyelitis. It is, therefore, suggested that appropriately used external fixation is a viable alternative to intramedullary nailing if designed and surgically applied using four design principles outlined in this paper. Furthermore, it is proposed that external fixation be designed and applied to meet these four principles.


Assuntos
Fixação Intramedular de Fraturas , Osteomielite , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tíbia , Fixação de Fratura/métodos , Consolidação da Fratura , Osteomielite/etiologia , Resultado do Tratamento , Fixadores Externos
9.
J Trauma Acute Care Surg ; 96(5): 694-701, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38227676

RESUMO

ABSTRACT: Patients with multisystem injuries are defined as multiply injured patients and may need multiple surgical procedures from more than one specialty. The importance of evaluating and understanding the resuscitation status of a multiple-injury patient is critical. Orthopedic strategies when caring for these patients include temporary stabilization or definitive early fixation of fractures while preventing further insult to other organ systems. This article will define multiple injuries and discuss specific markers used in assessing patients' hemodynamic and resuscitation status. The decision to use damage-control orthopedics or early total care for treatment of the patient are based on these factors, and an algorithm is presented to guide treatment. We will also discuss principles of external fixation and the management of pelvic trauma in a multiple-injury patient.


Assuntos
Traumatismo Múltiplo , Humanos , Traumatismo Múltiplo/terapia , Traumatismo Múltiplo/diagnóstico , Procedimentos Ortopédicos/métodos , Fixação de Fratura/métodos , Ressuscitação/métodos , Fraturas Ósseas/terapia , Fraturas Ósseas/cirurgia , Algoritmos , Hemodinâmica/fisiologia
10.
Eur J Trauma Emerg Surg ; 50(1): 215-219, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37405448

RESUMO

PURPOSE: Gustilo IIIB open tibial fractures are associated with significant risks of complications particularly nonunion and fracture-related infections (FRI) due to the severity of the injuries. The commonly adopted viewpoint is that a Gustilo IIIB open tibial fracture is a relative contraindication for internal fixation. However, this study aims to assess the veracity of this viewpoint. The objective of this study was to evaluate the impact of the definitive fixation technique on fracture nonunion and FRI rates in Gustilo IIIB open tibial fractures. In this study, we compared the rates of nonunion and FRI rates in grade IIIB open tibial fractures managed definitively with either mono-lateral external fixation or internal fixation. METHODS: The study was a multicenter retrospective comparative study undertaken in seven Nigerian tertiary hospitals. Following ethical approval, medical records of patients diagnosed with Gustilo IIIB open tibial fractures (between 2019 and 2021) were retrieved, patients who had a minimum of nine months of follow-up period and were found eligible had their relevant data entered into an online data collection form. Data obtained was analysed with SPSS version 23, and chi-square test was used to determine the statistical significance of differences observed between the two groups with regard to nonunion and FRI rates. P values less than 0.05 were considered statistically significant. RESULTS: Out of a total of 47 eligible patients, 25 patients were managed definitively with mono-lateral external fixation whilst 22 patients were managed with internal fixation. Five of the 25 patients (20%) managed with external fixation had nonunion whilst two cases of nonunion were recorded amongst the 22 patients (9.1%) treated with internal fixation. The difference between the two techniques with regard to nonunion rates was not statistically significant (P = 0.295). 12 out of 25 patients (48%) in the external fixation group had FRIs whilst 6 out of 22 patients (27.3%) in the internal fixation group had FRIs. The rates of FRIs of the two groups were not significantly different (P = 0.145). CONCLUSION: Our findings suggest that mono-lateral external fixation and internal fixation do not differ significantly with respect to rates of nonunion and fracture-related infections in Gustilo IIIB open tibial fractures.


Assuntos
Fraturas Expostas , Fraturas da Tíbia , Humanos , Fixação de Fratura/métodos , Fixadores Externos , Estudos Retrospectivos , Resultado do Tratamento , Fraturas Expostas/cirurgia , Fraturas da Tíbia/cirurgia
11.
Eur J Orthop Surg Traumatol ; 34(1): 161-166, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37386191

RESUMO

PURPOSE: Fracture blisters, a common soft-tissue complication of pilon fractures, are associated with post-operative wound infections, delays in definitive fixation, and alterations in surgical plan. The purpose of this study was to (1) identify the delay in surgery attributable to the presence fracture blisters and (2) investigate the relationship of fracture blisters to comorbidities and fracture severity. METHODS: Patients with pilon fractures at an urban level 1 Trauma center from 2010 to 2021 were identified. The presence or absence of fracture blisters was noted, along with location. Demographic information, time from injury to external fixator placement, and time to definitive open reduction internal fixation (ORIF) were collected. Pilon fractures were classified according to AO/OTA guidelines using CT imaging and plain radiographs. RESULTS: 314 patients with pilon fractures were available for analysis, eighty (25%) of whom were found to have fracture blisters. Patients with fracture blisters had longer time to surgery compared to those without fracture blisters (14.2 days vs 7.9 days, p < 0.001). A greater proportion of patients with fracture blisters had AO/OTA 43C fracture patterns, compared with those without fracture blisters (71.3% vs 53.8%, p = 0.03). Fractures blisters were less likely to be localized over the posterior ankle (12%, p = 0.007). CONCLUSION: The presence of fracture blisters in pilon fractures are associated with significant delays in time to definitive fixation and higher energy fracture patterns. Fracture blisters are less commonly located over the posterior ankle which may support the implementation of a staged posterolateral approach when managing these injures.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Fraturas da Tíbia , Humanos , Vesícula/etiologia , Resultado do Tratamento , Traumatismos do Tornozelo/cirurgia , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Fixação de Fratura/efeitos adversos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos
12.
Eur J Orthop Surg Traumatol ; 34(1): 489-497, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37632546

RESUMO

PURPOSE: The modified Kapandji technique has been proposed for fracture reduction in pediatric displaced distal radius fractures (DDRFs), but evidence is sparse. The purpose of this study was to evaluate our outcomes and complications, critically and systematically, when performing the modified Kapandji technique in pediatric DDRFs. Using this technique since 2011, we asked: (1) What is the quality of fracture reduction using this technique? (2) How stable is fracture alignment with this technique? (3) What are the postoperative complications and complication rates? METHODS: Retrospective observational study of 195 pediatric patients treated with the modified Kapandji technique. Quality of fracture reduction, fixation type (intrafocal, combined, or extrafocal), and coronal/sagittal angulation were recorded at surgery and healing. Perioperative complications were graded. Patients were stratified by fracture (metaphyseal or Salter-Harris) and fixation type, as well as age (≤ 6 years; 6 to 10 years; > 10 years). RESULTS: Fracture reduction was 'good' to 'anatomical' in 85% of patients. 'Anatomical' fracture reduction was less frequent in metaphyseal fractures (21% vs. 51%; p < .001). Mean angulation change was higher in metaphyseal fractures in both the sagittal (p = .011) and coronal (p = .021) planes. Metaphyseal fractures showed a higher mean change in sagittal angulation during fracture healing for the 'intrafocal' group. We observed a 15% overall complication rate with 1% being modified Sink Grade 3. CONCLUSION: The modified Kapandji technique for pediatric DDRFs is a safe and effective treatment option. Metaphyseal fractures that do not involve the physis should be treated with extrafocal or combined wire fixation. Complications that require additional surgical treatment are rare. LEVEL OF EVIDENCE: Level of evidence IV.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Criança , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fios Ortopédicos , Fixação de Fratura/métodos
13.
Eur J Orthop Surg Traumatol ; 34(2): 809-814, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37713000

RESUMO

INTRODUCTION: While pediatric femoral shaft fractures account for less than 2% of all fractures in children, they are the most common pediatric fracture requiring hospitalization. Management of pediatric femoral shaft fractures is challenging, with various treatment options relating to severity and patient age. The last few decades have seen an increased supply of pediatric orthopedic surgeons (POS) along with increased referral rates. However, there continues to be a maldistribution of POS throughout the country. This study sought to determine outcomes following femoral shaft fracture repair by POS compared to non-pediatric trained orthopedic surgeons. METHODS: The National Surgical Quality Improvement Program-Pediatric database was queried to identify pediatric patients who underwent open treatment of femoral shaft fracture from 2012 to 2019. Differences in patient demographics, comorbidities, and postoperative complications were assessed and compared between patients who were treated by pediatric subspecialty-trained orthopedic surgeons and those treated by non-pediatric orthopedic surgeons. Bivariate and multivariable regression analyses were utilized. RESULTS: Of the 5862 pediatric patients who underwent femoral shaft fracture treatment, 4875 (83.2%) had their surgeries performed by a POS whereas 987 (16.8%) were operated on by a non-pediatric surgeon. POS were more likely to operate on patients with a higher American Society of Anesthesiologists classification (p < 0.001) and those with medical comorbidities, including gastrointestinal (p = 0.022) and neurological (p < 0.001). After controlling for baseline patient characteristics on multivariable regression analysis, patients treated by non-pediatric orthopaedic surgeons are at an increased risk of prolonged hospital stay (OR 2.595; p < 0.001) when compared to patients operated on by POS. CONCLUSION: The results indicated that patients undergoing surgical treatment for a femoral shaft fracture by a non-pediatric trained orthopedic surgeon were at increased risk of a prolonged hospital stay compared to those being treated by POS. Additionally, POS were more likely to operate on more difficult patients with increased comorbidities.


Assuntos
Fraturas do Fêmur , Cirurgiões Ortopédicos , Ortopedia , Cirurgiões , Humanos , Criança , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fixação de Fratura/métodos , Estudos Retrospectivos
14.
J Hand Surg Eur Vol ; 49(3): 310-315, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37666217

RESUMO

We assessed operatively treated closed distal radial fractures to identify independent risk factors for surgical site infection after treatment. A retrospective review was carried out of 531 operatively treated closed distal radial fractures over a 5-year period. Multiple logistic regression was performed with infection as the dependent variable, using a stepwise regression procedure to select variables to construct the final model. In total, 19 (3.6%) fractures were complicated by postoperative surgical site infection. Uncontrolled diabetes with HbA1c >7, the presence of external fixation or external Kirschner wires, and tobacco use were significant independent predictors of infection. Age and time in the operating room were also statistically significant predictors but deemed to be not clinically meaningful.Level of evidence: IV.


Assuntos
Fraturas do Rádio , Infecção da Ferida Cirúrgica , Humanos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Fixação de Fratura/efeitos adversos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Fios Ortopédicos , Fatores de Risco , Resultado do Tratamento
15.
Eur J Orthop Surg Traumatol ; 34(1): 353-361, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530905

RESUMO

BACKGROUND: The management of failed tibial fracture fixation remains a challenge for orthopaedic surgeons. This study investigate the utility and outcomes of circular external fixation in the management of failed internal fixation of tibial fractures. METHODS: Retrospective review of a prospectively collected database of a complex limb reconstruction unit at a major trauma centre was done during December 2022. Patients with failed internal fixation of tibial fracture who underwent revision surgery with circular external fixation frame were included. RESULTS: 20 patients with a mean age of 47.8 ± 16.5 years (range: 15-69) were included. Fourteen (70.0%) patients had failed plate and screws fixations, and the remaining six (30.0%) failed intramedullary nail fixation. The most common indication for revision surgery was development of early postoperative surgical site infection (5 patients; 25.0%). The mean duration of frame treatment was 199.5 ± 80.1 days (range = 49-364), while the mean follow-up duration following frame removal was 3.2 ± 1.8 years (range = 2-8). The overall union rate in this series was 100%; and all infected cases had complete resolution from infection. The total number of complications was 11, however, only two complications required surgical intervention. The most common complications reported were pin site infection (6; 30.0%) and limb length discrepancy of 2 cm (2; 10.0%). CONCLUSIONS: Circular external fixation is a reliable surgical option in the treatment of failed internal fixation of tibia fractures. This technique can provide limb salvage in complex infected and noninfected cases with a high union rate and minimal major complications.


Assuntos
Tíbia , Fraturas da Tíbia , Humanos , Adulto , Pessoa de Meia-Idade , Tíbia/cirurgia , Fixação de Fratura/efeitos adversos , Fixação de Fratura/métodos , Fixadores Externos , Resultado do Tratamento , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Estudos Retrospectivos
16.
Orthopedics ; 47(2): 71-78, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37561102

RESUMO

The purpose of this review was to determine whether there is a benefit to early weight bearing or mobilization in surgically treated ankle fractures. All randomized controlled trials that analyzed early vs delayed weight bearing and/or mobilization after an ankle surgery were included. The primary outcome measure was the pooled Olerud Molander Ankle Score 1 year postoperatively. No significant differences in ankle function were found at 1 year postoperatively between early and delayed weight bearing and mobilization. The 12-week results demonstrated superior early ankle function scores for patients who had early weight bearing. Patients who had early mobilization were at increased risk for postoperative complications. In surgically treated ankle fractures, early weight bearing resulted in improved short-term ankle function scores. [Orthopedics. 2024;47(2):71-78.].


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/cirurgia , Tornozelo , Ensaios Clínicos Controlados Aleatórios como Assunto , Fixação Interna de Fraturas , Suporte de Carga , Resultado do Tratamento , Fixação de Fratura/métodos
17.
Orthop Surg ; 16(1): 234-244, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38041507

RESUMO

OBJECTIVE: Closed reduction combined with external fixation is a frequently utilized approach for treating distal radial fractures in adults. Nonetheless, the potential for re-displacement following external fixation remains. Analyzing the factors influencing re-displacement after nonsurgical treatment of distal radial fractures in adults is vital for preventing re-displacement and making prognostic assessments. METHODS: A retrospective analysis was performed on 884 patients who underwent nonsurgical treatment for distal radius fractures in the reduction room of the Orthopedics and Traumatology Department of Integrated Traditional Chinese and Western Medicine at Tianjin Hospital, Tianjin, China, between July 2019 and December 2022. Patients were categorized into two groups, namely displaced and nondisplaced, based on radiographic outcomes. Factors affecting fracture re-displacement were examined, including sex, age, side, AO/OTA type, external fixation, and radiographic outcomes at pre-reduction and immediate reduction. Logistic regression analysis was employed to identify the risk factors for fracture re-displacement, and ROC curves were constructed. RESULTS: Among the 884 patients, 563 (63.69%) experienced re-displacement after fracture reduction. There were no statistically significant differences (p > 0.05) between the two groups in terms of gender, external fixation method, and palmar tilt angle at pre-reduction and immediate reduction, while significant differences (p < 0.05) were observed in age, side, AO/OTA type, and radial inclination, radial length, and radiographic outcomes of ulnar variance at pre-reduction and immediate reduction. Multifactorial logistic regression analysis revealed that age (odds ratio [OR] = 1.027, p < 0.001), AO/OTA type (OR = 2.327, p = 0.005), ulnar variance at pre-reduction (OR = 1.142, p = 0.048), and ulnar variance at immediate reduction (OR = 1.685, p < 0.001) were significant factors (p < 0.05) associated with re-displacement following nonoperative treatment of adult distal radius fractures. For patients aged ≥60 years, the amount of missing radiographic outcomes was positively correlated with age. The receiver operating characteristic curve demonstrated that age ≥65.5 years, ulnar variance >3.26 mm at pre-reduction, and ulnar variance >2.055 mm at immediate reduction were high-risk factors for fracture re-displacement. CONCLUSIONS: Nonsurgical treatment of distal radius fractures exhibits a higher rate of re-displacement. Age, AO/OTA type, pre-reduction, and immediate reduction ulnar variance are key factors predicting fracture re-displacement.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Adulto , Humanos , Estudos Retrospectivos , Fraturas do Rádio/terapia , Fraturas do Rádio/cirurgia , Fixação de Fratura/métodos , Prognóstico , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Placas Ósseas , Amplitude de Movimento Articular
18.
Sci Rep ; 13(1): 21890, 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-38082020

RESUMO

Complex lower extremity trauma reconstruction remains a challenge. This study used an internal fixation composite structure of antibiotic cement plates as a temporary fixation to treat lower extremity Grade III open fractures; thus, reducing the treatment period and complications of external fixation. We aimed to assess the safety and efficacy of this technique in the initial surgery stage. Between January 2018 and March 2021, 20 patients with Gustilo grade IIIB/C open fractures received an antibiotic cement-coated locking plate as a temporary internal fixator during initial surgery. Thorough debridement and temporary internal fixation were performed with a 3.5-mm system antibiotic cement-coated locking plate. Ten patients required free bone fragment removal, followed by bone cement packing. The final stage involved internal fixation and wound repair with a free anterolateral thigh flap. Clinical and imaging results were retrospectively analysed. The repair time ranged 1-7 days. All flaps survived. Two patients experienced wound infection, and one developed severe bone infection 3 months after three-stage bone graft surgery. Autologous cancellous bone grafting was performed on 10 patients with bone defects 6 weeks after surgery. Bone union was universally achieved after 1 year. This method proved safe and effective, successfully repairing Grade III open fractures of the lower extremity 1-7 days post-treatment.


Assuntos
Fraturas Expostas , Retalhos de Tecido Biológico , Fraturas da Tíbia , Humanos , Fraturas Expostas/cirurgia , Antibacterianos/uso terapêutico , Cimentos Ósseos/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/tratamento farmacológico , Fixação Interna de Fraturas/métodos , Placas Ósseas , Fixação de Fratura/métodos
19.
BMC Musculoskelet Disord ; 24(1): 962, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38082305

RESUMO

BACKGROUND: Open distal tibial fractures pose significant challenges regarding treatment options and patient outcomes. This retrospective single-centre study aimed to compare the stability, clinical outcomes, complications, and financial implications of two surgical interventions, namely the external locking plate and the combined frame external fixator, to manage open distal tibial fractures. METHODS: Forty-four patients with distal open tibial (metaphyseal extraarticular) fractures treated between 2020 and 2022 were selected and formed into two main groups, Group A and Group B. Group A (19 patients) are patients that underwent treatment using the external locking plate technique, while Group B (25 patients) received the combined frame external fixator approach. Age, gender, inpatient stay, re-operation rates, complications, functional recovery (measured by the Johner-Wrush score), pain ratings (measured by the Visual Analogue Scale [VAS]), and cost analyses were evaluated for each group. Statistical analyses using SPSS were conducted to compare the outcomes between the two groups. RESULTS: The research found significant variations in clinical outcomes, complications, and cost consequences between Group A and Group B. Group A had fewer hospitalisation periods (23.687.74) than Group B (33.5619.47). Re-operation rates were also considerably lower in Group A (26.3%) than in Group B (48%), owing to a greater prevalence of pin-tract infections and subsequent pin loosening in the combination frame external fixator group. The estimated cost of both techniques was recorded and analysed with the locking average of 26,619.69 ± 9,602.352 and the combined frame average of 39,095.64 ± 20,070.077. CONCLUSION: This study suggests that although the two approaches effectively manage open distal tibia fractures, the locking compression plate approach (Group A) has an advantage in treating open distal tibia fractures. Shorter hospitalisation times, reduced re-operation rates, and fewer complications will benefit patients, healthcare systems, and budget allocation. Group A's functional recovery results demonstrate the locking plate technique's ability to improve recovery and patient quality of life. According to the cost analysis, the locking plate technique's economic viability and cost-effectiveness may optimise healthcare resources for open distal tibia fractures. These findings might improve patient outcomes and inform evidence-based orthopaedic surgery.


Assuntos
Fraturas Expostas , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Fixadores Externos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixação de Fratura/efeitos adversos , Fixação de Fratura/métodos , Fraturas Expostas/cirurgia , Placas Ósseas , Resultado do Tratamento
20.
J Orthop Surg Res ; 18(1): 846, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940977

RESUMO

AIMS: Frozen shoulder and proximal humeral fracture can cause pain, stiffness and loss of function. The impact of these symptoms on patients can be measured using the comprehensively validated, 12-item Oxford Shoulder Score (OSS). Evidence suggests that pain and function may have a differential impact on patients' experience of shoulder conditions, and this may be important for clinical management. We therefore explored the factor structure of the OSS within the UK FROST and PROFHER trial populations. METHODS: We performed exploratory factor analysis (EFA), followed by confirmatory factor analysis (CFA), on baseline UK FROST data from 490 of the 503 trial participants. Data at 6 months post-randomisation were used for 228 of the 250 participants for the PROFHER trial. RESULTS: UK FROST factor extraction results, using Velicer's Minimum Average Partial and Horn's Parallel Analysis tests, suggested a unifactorial solution, but two factors were weakly indicated by the less reliable 'Kaiser's eigenvalue > 1' and scree tests. We explored this further using EFA. Eight items (2 to 7, 9 and 10) loaded onto a 'Function' factor, three on a 'Pain' factor (1, 8 and 12) and item 11 cross-loaded. However, one- and two-factor models were rejected in CFA. Factor extraction of PROFHER data at 6 months demonstrated a single first-order factor solution, which was also subsequently rejected in CFA. CONCLUSION: Insufficient evidence was found, within the constraints of the data available, to support the use of 'Pain' and 'Function' sub-scales of the OSS in either patient population.


Assuntos
Fraturas do Ombro , Ombro , Humanos , Resultado do Tratamento , Fixação de Fratura/métodos , Fraturas do Ombro/diagnóstico , Dor , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA